Homepage | Login | Want to open an account?
Product Search
Quick Find

Chemical oxygen demand analysis set : Aqualytic PC Compact COD Vario Photometer

Chemical oxygen demand analysis set : Aqualytic PC Compact COD Vario Photometer
 Cat. NoDescrtiptionPack SizePriceQuantity
WT/75002 PC COMPACT COD VARIO COMPLETE WITH CARRYING CASE each £582.12

Chemical Oxygen Demand (COD) is a critical environmental parameter and is widely used as a measure of the pollutants in discharged waste waters. COD is also used for assessing the efficiency of water treatment plants and the load placed on these plants by incoming waste streams.
COD analysis gives a rapid indication of the level of both organic and inorganic oxygen demanding pollutants. COD testing must be performed under tightly controlled conditions of temperature and time.
Reagecon offer all of the components required for rapid, confident analysis of COD. The measurement system complies with ISO 15705 & Standard Method 5220 D for chemical composition and for the requirement that digestion must take place at 150°C for 2 hours. Reagecon’s COD set comprises of:
  • The Aqualytic PC Compact COD Vario Photometer.
  • 8 place & 25 place Thermoreactors (AL32 & AL38).
  • 16mm diameter COD Reagent vials, covering 3 different measurement ranges.
  • A comprehensive range of COD standards. Aqualytic PC Compact COD Vario Photometer With 3 measuring ranges, accurate analysis of all samples is possible. The PC Compact COD Vario uses two LED light sources – these combine wavelength accuracy with outstanding durability.
  • Rapid analysis - 3 second measuring cycle.
  • Accurate - high quality LED light sources and photo-sensor ensure reliable results.
  • Compact and easy to use.
    Technical specifications
    Meas. Cycle Approx. 3 seconds
    DisplayLCD
    OpticsTemperature-compensated LEDs  (1 = 605nm, 2 = 430nm), and photo-sensor amplifier in waterproof sample chamber
    Power Supply9V powerpack battery providing 40 hours operation
    Auto - OFFAutomatic switch-off approx. 5 minutes after last keypress
    Ranges0 – 150mg/l O2 ±3.5%
    ~0 – 1500mg/l O2 ±3.5%
    ~0 –15000mg/l O2 ±3.5%
    Dimensions (L x W x H)190 x 110 x 55mm
    WeightBase unit approx. 0.4kg
    Environmental Conditions Temperature:0 – 40°C
    Rel. humidity:30 – 90% (non-condensing)
    CE- ConformityEN 50081-1
    ~VDE 0839 part 81-1: 1993-03
    ~EN 50082-2
    ~VDE 0839 part 82-2: 1996-02